Every factual number in the model town has a source, or is labelled a placeholder. This page is generated from the project's sources file.

Values that are placeholders

Parameters and sources

ParameterValueUnitSourceChecked
Every city.json value NOT listed below——PLACEHOLDER. The file's placeholders list names them: population, districts, buildings.count, buildings.floors, buildings.footprint_m2, buildings.annual_kwh_each (electricity per building), solar, wind, storage, water.daily_shape, water.towers, water.treatment, transport.cars, transport.ev_share, transport.buses, transport.electric_bus_share, transport.chargers, transport.v2g_*, green.area_m2, green_params pocket-park rows, recycling.capacity_t_per_year. They size the reference city and are design choices, not measurements. The site shows a "placeholder values" note on every card that uses one.—
Hourly PV output per kWp, 2 m air temperature, 10 m wind speed (web/public/weather/brussels.csv)8,760 hourly rows, calendar year 2023 (not a leap year)kW/kWp, deg C, m/sPVGIS 5.3 seriescalc, EU Joint Research Centre (https://re.jrc.ec.europa.eu/api/v5_3/seriescalc). Radiation database PVGIS-SARAH3, meteorology ERA5. Query: lat 50.85, lon 4.35, startyear=endyear=2023, pvcalculation=1, peakpower=1 kWp, loss=14 %, fixed mounting, angle=35, aspect=0 (south), crystalline silicon, horizon from DEM. Hourly stamps are UTC (xx:10), row 0 = 1 January 00:00; no daylight-saving shift.2026-11-10
PV tilt 35 degrees, azimuth south35, 0degreesModelling choice for a typical fixed Brussels array, not a measurement. The "optimal angle" option gave a different slope for each endpoint (36 versus 39 degrees), so an explicit angle was used.2026-11-10
Wind shear exponent wind_shear_alpha0.2-Modelling assumption from spec 02 (power-law scaling of 10 m wind to hub height, open terrain). Not measured.2026-11-10
Turbine hub height hub_height_m100mPlaceholder for the reference city.-
Distance one car drives per day km_per_car_day45.4km/dayCar-Pass data reported by New Mobility, "Car use in Belgium still 7.5 % lower than before pandemic", 13 Feb 2023: the average passenger car covered 16,589 km in 2022 (divided by 365). https://newmobility.news/en/2023/02/13/car-use-in-belgium-still-75-lower-than-before-pandemixc/ . Covers all passenger cars, not only electric ones.2026-11-10
Electricity use of an electric car kwh_per_km0.21kWh/kmWeiss, Winbush, Newman, Helmers, "Energy Consumption of Electric Vehicles in Europe", Sustainability 16(17):7529, 2024. Real-world average over 342 models sold in Europe: 21 +/- 4 kWh per 100 km. https://doi.org/10.3390/su16177529 . This is energy used by the vehicle; charger losses are not modelled.2026-11-10
Distance one bus drives per day km_per_bus_day218km/dayViriCiti, analysis of 79 12 m battery-electric buses in 7 Dutch cities (2020), reported by Sustainable Bus. https://sustainable-bus.com/news/electric-bus-consumption-energy-report-viriciti2026-11-10
Electricity use of an electric bus bus_kwh_per_km1.15kWh/kmSame ViriCiti study, 12 m buses, all seasons average.2026-11-10
Charger windows, shares of charging, charger counts and powers (chargers)home 18:00-07:00 share 0.8, public 08:00-18:00 share 0.2, depot 22:00-05:00 share 1-PLACEHOLDER, not sourced.-
v2g_share, v2g_kwh_per_car, v2g_roundtrip_eff0.1, 10 kWh, 0.9-PLACEHOLDER, not sourced.-
Heating base temperature heat.t_base_c15deg CEurostat degree-day metadata (https://ec.europa.eu/eurostat/cache/metadata/en/nrg_chdd_esms.htm) and KMI/IRM degree-days (https://www.meteo.be/fr/services/produits-et-services/degres-jours). Confidence high. Research file A.2026-11-10
Hot-water share of heat heat.hot_water_share0.16shareOdyssee-MURE Belgium profile, 2023: hot water 14 % and space heating 72 % of household energy (https://odyssee-mure.eu/publications/efficiency-trends-policies-profiles/belgium.html), 14/86 = 0.163; Wallonia domestic balance 2019 gives 0.14 to 0.15 (https://energie.wallonie.be/servlet/Repository/bilan-domestique-et-equivalents-2019-v2.pdf?ID=67309). Constant over the year is a modelling assumption of spec 04. Confidence medium.2026-11-10
Heat pump COP cop_a, cop_b, cop_min, cop_max2.07, 0.058 per deg C, 1.78, 2.94COPStraight-line fit (least squares, -5 to +15 deg C, within 0.04 COP) to the air-source quadratic of Staffell et al. 2012, Energy & Environmental Science 5:9291 (https://pubs.rsc.org/en/content/articlehtml/2012/ee/c2ee22653g), coefficients read in secondary copies only (Hehar et al., Energies 18(3):738, 2025, https://www.mdpi.com/1996-1073/18/3/738). Sink temperature 55 deg C (radiators). A DECISION: a 45 deg C sink would give a = 2.65, b = 0.0706, min 2.30, max 3.71, and matches the German field mean of about 2.9 (Fraunhofer ISE). Confidence low to medium; this is the main sensitivity of the heat results.2026-11-10
Annual heat per building annual_heat_kwh_eachhomes 130, offices 120, schools 138 kWh per m2 of floor area (floors x footprint): homes_north 18,200, homes_south 20,800, homes_centre 39,000, offices 192,000, schools 414,000 kWhkWh/building/yearHomes: Wallonia domestic energy balance 2019, climate-normalised single-family gas house 15.4 MWh heating plus 2.8 MWh hot water = 18.2 MWh, read as 130 kWh/m2 for a 140 m2 house; Wallonia not Brussels, floor area of the source houses unknown. The same per-m2 value is applied to the centre's flats. Offices: UK CIBSE TM46 typical 120 kWh/m2 (via https://assets.publishing.service.gov.uk/media/5a7e1520e5274a2e8ab45b9e/EED_regs_-_benchmark_heat_demand_paper_-_261114_.pdf), Dutch cross-check 103 to 128; no Belgian office stock figure found. Schools: Brussels school stock 2009, 358,270,600 kWh fuel over 2,596,800 m2 = 138 kWh/m2 (Brussels Environment PLAGE sheet). Confidence medium (homes, schools), low (offices). The values are FINAL gas energy, not useful heat.2026-11-10
Gas boiler efficiency1 (gas heat counted as the fuel energy, which is what the sources give)-The sourced heat values are final gas energy, so gas_kwh is fuel burned and the gas CO2 factor applies to it directly. Heat pump groups are given the same number as heat to deliver, which slightly overstates their heat demand (no sourced stock boiler efficiency; Ecodesign minimum 86 % is on the gross basis).2026-11-10
Gas CO2 carbon.gas_kg_co2_per_kwh0.202kg CO2/kWh fuelVEKA standard factor 56.1 t CO2/TJ (https://www.vlaanderen.be/veka/energie-en-klimaatbeleid-in-cijfers/co2-emissiefactoren-calorische-onderwaarden-en-soortelijke-gewichten-van-fossiele-brandstoffen-en-elektriciteit), x 0.0036 GJ/kWh; consistent with IPCC 2006 (56,100 kg/TJ, net calorific basis). Combustion only: upstream emissions are excluded. Confidence high.2026-11-10
Grid CO2 carbon.grid_kg_co2_per_kwh0.190kg CO2e/kWhAwAC (Walloon Air and Climate Agency), FE Elec AWAC, March 2026, Belgian grid consumption 2024, direct emissions, not life cycle (https://awac.be/wp-content/uploads/2026/03/FE_Elec_AWAC_mars20262e.pdf). Other published values differ: Elia 2024 life cycle 0.128, Electricity Maps 0.153. Confidence medium.2026-11-10
Drinking water per person water.daily_m3_per_person0.085m3/person/dayBRUGEL, Rapport annuel 2024 Eau: 31.07 m3 per inhabitant per year at the domestic tariff, about 85 L/day (https://brugel.brussels/publication/document/rapports/2025/fr/Rapport-annuel-2024-Eau.pdf). Households only; Brussels all users is 133 L. Confidence high for the figure.2026-11-10
Electricity of water supply water.kwh_per_m3_supply0.50kWh/m3Roest, Hofman, van Loosdrecht, H2O 43(25/26), 2010: Dutch drinking-water production and distribution 0.50 kWh/m3 (distribution 0.11); Vewin 2024 gives 0.51 kWh/m3 energy (https://www.vewin.nl/wp-content/uploads/2025/09/25274-VEW-Kerngegevens-drinkwater-2025-A6-EN-web.pdf). Netherlands, no Belgian value found. Confidence medium.2026-11-10
Electricity of wastewater treatment water.kwh_per_m3_treatment0.37kWh/m3Same Roest et al. 2010: Dutch plants 2008, 721,000 MWh for 1,928 million m3 = 0.374 kWh/m3. Sewer pumping (0.11) is not modelled. Netherlands, no Belgian value found. Confidence medium.2026-11-10
Water daily_shape (24 relative weights, morning and evening peaks)see city.json-PLACEHOLDER. No citable numeric hourly profile found; the two daily peaks are supported qualitatively by Blokker et al. 2010 (Dutch), Cranfield smart-meter study and Gurung et al. 2014.-
Water tower pump_m3_per_hour, volume_m3; treatment capacity_m3_per_day250, 1500, 3000m3/h, m3, m3/dayPLACEHOLDER design values for the reference city.-
Rainfall green_params.annual_rain_m0.8371m/yearKMI/IRM climate statistics Uccle 1991-2020, 837.1 mm (https://opendata.meteo.be/ftp/climate/climate_statistics/climate_INS21016_9120_nl.pdf). Confidence high.2026-11-10
Carbon uptake green_params.co2_t_per_m2_yearpark 0.000165, forest 0.000195, green roof 0.00018, pocket park 0.000165t CO2/m2/yearPark: Thoelix et al., Biogeosciences 22:725, 2025, Helsinki modelled net exchange mean 45.2 g C/m2/yr x 3.664 (https://doi.org/10.5194/bg-22-725-2025), low confidence. Forest: Belgium National Inventory Document 2025, 1,302.11 Gg CO2 over 668.0 kha = 1.95 t CO2/ha/yr, medium-high. Green roof: Getter et al., Environ. Sci. Technol. 43:7564, 2009, substrate carbon gain 50 g C/m2/yr (my division of their two-year figure), medium. Pocket park: NO measurement found; the park value is used as a PROXY and listed as a placeholder.2026-11-10
Stormwater retention green_params.retentionpark 0.80, forest 0.90, green roof 0.40, pocket park 0.80share of rainGreen roof: Stovin, Poe, Berretta, J. Environ. Manage. 131:206, 2013, Sheffield 838 mm/yr gives 0.397 (https://eprints.whiterose.ac.uk/78236/), medium. Park (some paving) and forest: US FHWA generic runoff split (natural cover runoff 10 %, 10-20 % impervious runoff 20 %) and Flemish forest evapotranspiration share 0.60 as a floor (https://www.environment.fhwa.dot.gov/env_topics/water/ultraurban_bmp_rpt/fig1txt.htm), low to medium. Retention counts evapotranspiration and infiltration as retained, and is absolute retention, not a benefit against an alternative surface. Pocket park: PROXY (park value), listed as a placeholder.2026-11-10
Cooling green_params.cooling_k_per_green_fractionabsentK per unit green fractionLEFT OUT on purpose. The only per-fraction values (Leuven -1.1 deg C per unit tree cover, Beele et al. 2024, abstract only; Florence) come from 50-250 m buffers and cannot be applied to a district without overstating the cooling. The report says cooling_available = false and the green cards say so.2026-11-10
Embodied carbon carbon.embodied_kg_co2e_per_m2timber 509, masonry 645, concrete 622, steel 685kg CO2e/m2 gross floor areaONE dataset: EU-ECB, Roeck et al. 2022, Table 3 means (https://zenodo.org/records/5895051, doi 10.5281/zenodo.5895051). Scope: whole life over 50 years, stages A1-A5, B1-B4, C1-C4, module D and operational energy excluded, all uses together (about 85 % residential). Mapping: timber = frame wood (n 76), masonry = massive brick (n 407), concrete = frame concrete (n 46), steel = frame steel (n 4). Confidence medium; steel low. The scope is whole life, not A1-A5 only, so the payback compares a whole-life figure with one year of operation.2026-11-10
Waste recycling_params.waste_kg_per_person_year, capture_ratematerials (dry recyclables) 131.87 kg at 0.83; organic (GFT) 91.44 kg at 0.485kg/person/year; shareOVAM sorting analysis 2019-2021 (https://publicaties.vlaanderen.be/view-file/49047) plus OVAM household waste 2025 annex 5.2 (https://ovam.vlaanderen.be/cijfers-huishoudelijk-afval): generated = collected separately + still in the residual bin, capture = collected / generated, Flanders 2020. Flanders, not Brussels; PMD capture has risen since. Confidence medium (Flanders), low (Brussels).2026-11-10
Car life recycling_params.ev_life_years18.1yearsHeld et al., European Transport Research Review 13:9, 2021, Western Europe mean Weibull lifespan (https://doi.org/10.1186/s12544-020-00464-0). Belgium alone is 11.7 but counts exports. Conventional-car value applied to electric cars. Confidence medium.2026-11-10
EV pack recycling_params.pack_kwh70kWhIEA Global EV Outlook 2026, EU new battery cars 2025 (https://www.iea.org/reports/global-ev-outlook-2026/electric-vehicle-batteries). Packs retiring later come from older, smaller packs, so this overstates. Confidence high for new cars.2026-11-10
Remaining capacity remaining_capacity_share, reuse share reuse_share0.80, 0.50shareFallah and Fitzpatrick, J. Remanufacturing 14:155, 2024 (https://doi.org/10.1007/s13243-024-00137-4): 0.80 is the literature convention for retirement, about 50 % of packs reusable at the 80 % state-of-health threshold (Ireland, 2050 model). Confidence low.2026-11-10
Pack specific energy pack_kwh_per_kg0.126kWh/kgOne measured vehicle, Tesla Model 3 LFP pack 458 kg, Rosenberger et al., World Electric Vehicle Journal 15(6):268, 2024 (https://mdpi.com/2032-6653/15/6/268). No fleet average found. Confidence low.2026-11-10
Recycling centre capacity_t_per_year (9,000 / 400 / 2,500)see city.jsont/yearPLACEHOLDER design values for the reference city; the scorecard's recycling utilisation depends on them.-
Brussels buildings: UrbIS 3D Constructions (solids, faces)LoD 2 geometry, no height attribute; heights derived (see next row)mUrbIS, Brussels-Capital Region (publisher's name to be written exactly as the product page gives it at the real build), product record https://geobru-geonetwork.irisnet.be/geonetwork/srv/api/records/e9ec2aa4-cffd-11ee-bccc-00090ffe0001 , product specification https://urbisdownload.datastore.brussels/UrbIS/TechSpec/3D_TechSpec_FR20240409.pdf . Licence CC0 as stated for this product (read during step 0 of package 14); product data date is NOT yet recorded because the data has not been downloaded (the sandbox cannot reach the service). Fill the date and version in sources.json at the real build.2026-11-19
Building height h_m, base_m (derived)top of roof faces minus lowest ground face, rounded to 0.1 mmA DEFINITION of this project, made because the product has no height field: index.json carries the full text as height_definition. Not an accuracy-stated measurement; the product gives no accuracy for it. Labelled measured in tiles because it comes from the surveyed geometry, never from a guess.2026-11-19
Brussels addresses and 2D buildings: UrbIS Parcels and buildingsstreet names FR/NL, house number, box, link to building-UrbIS download service, https://urbisdownload.datastore.brussels . The download service's licence statement (https://geobru-geonetwork.irisnet.be/geonetwork/srv/api/records/2db76400-2d49-11ee-a176-010101010000) says CC0; NOT yet confirmed on this product's own page. Confirm before any tile is published.-
Brussels roads: UrbIS Transport networks (street axes)classes H, MER, MAR, IDR, DC, DR, T-UrbIS download service, https://urbisdownload.datastore.brussels . Licence as for the other UrbIS products, NOT yet confirmed on its own page.-
Road class mapping (UrbIS HIERARCHY to spec 17 classes)H to ring; MER, MAR, IDR to avenue; DC, DR to street; T not a road for cars-PROVISIONAL. Evidence: the six codes match the six levels of the regional mobility catalogue's hierarchy (https://data-mobility.irisnet.be/info/Hierarchy), but the UrbIS product specification (Network_TechSpec_FR20240408.pdf) has not been read. The tool keeps the source code (src_class) so the table can be corrected without a rebuild of the sources.2026-11-19
Brussels green and water: UrbIS Land cover (TYPE GB, FO, CE green; WB water)--UrbIS download service, https://urbisdownload.datastore.brussels . Codes from the product description; licence NOT yet confirmed on its own page.-
Default storey height (tile set default_storey_height_m)3.0mPLACEHOLDER, not sourced. Used only to draw a building that has no height; the site labels it. A sourced value is needed before it is shown as a figure.-
Static host limits for /city/ (hosting check, spec 14)20,000 files per version on the free plan, 100,000 on a paid plan; 25 MiB per filefiles; MiBCloudflare Workers static assets, https://developers.cloudflare.com/workers/platform/limits/ and changelog 2025-09-02. Applies only if lemonergy.com/city is served from Cloudflare Workers; the host is not decided.2026-11-19
Hourly global, beam and diffuse horizontal irradiance (web/public/weather/brussels_irradiance.csv)8,760 hourly rows, 2023W/m2PVGIS 5.3 seriescalc, EU Joint Research Centre (https://re.jrc.ec.europa.eu/api/v5_3/seriescalc). Radiation PVGIS-SARAH3, meteorology ERA5. Query: lat 50.85, lon 4.35, startyear=endyear=2023, angle=0 (horizontal plane), usehorizon=0, components=1. Columns Gb(i) (beam on the plane, here horizontal beam) and Gd(i) (diffuse) saved as bhi_w_m2 and dhi_w_m2; ghi_w_m2 is their sum, kept to 0.1 W/m2 (five hours differ from the sum of the two rounded columns by 0.1) (the ground-reflected column Gr(i) is zero on a horizontal plane). Stamps UTC xx:10, row 0 = 1 January 00:00. The beam normal irradiance is derived as horizontal beam divided by the sine of the sun height (sun heights below 2 degrees are not used).2026-11-19
Sun position (crates/city-core/src/sun.rs)PSA algorithm, 2020 coefficients, evaluated at hh:10 UTdegreesBlanco-Muriel, Alarcon-Padilla, Lopez-Moreno, Valera, "Computing the solar vector", Solar Energy 70(5):431-441, 2001; coefficients updated in Blanco, Milidonis, Bonanos, Solar Energy 212, 2020. The coefficients were typed from the papers, not downloaded, and the NREL SPA worked example could not be fetched, so the check is against PVGIS (see below) and against astronomical facts (solstice and equinox noon, sunrise and sunset directions).2026-11-19
Isotropic sky diffuse modelview factor of the sky dome times diffuse horizontal irradiance-Liu and Jordan, "The interrelationship and characteristic distribution of direct, diffuse and total solar radiation", Solar Energy 4(3):1-19, 1960 and 1963 follow-up. Chosen for simplicity: it has no circumsolar part, so it under-estimates diffuse light on tilted south planes (measured below).2026-11-19
Ground albedo site_params.albedo0.2-PLACEHOLDER. 0.2 is the value PVGIS uses as default for the reflected term (not re-verified in its documentation).-
PV module efficiency site_params.module_efficiency0.20-PLACEHOLDER, not sourced.-
Usable share of a roof site_params.usable_roof_fraction0.5-PLACEHOLDER, not sourced.-
Performance factor site_params.performance_factor0.86-One minus the 14 % system loss that the PVGIS query for the weather file uses (spec 02). The hourly irradiance is not reduced by PVGIS's temperature and low-light effects, so this one factor covers all of them.2026-11-19
Site grid and angular resolution, adjacency tolerance, minimum sun height1.0 m, 2 degrees, 0.3 m, 2 degreesm, degreesNumerical choices of this project, not measurements. The 2 degree minimum sun height keeps the beam normal irradiance finite near the horizon.-
Road class speed limits road_classes.<class>.speed_kmhring 120, avenue 50, street 30, zone 20, rural 70km/hBelgian default limits. Ring: motorway and roads with two or more lanes each way and a median, 120 (Your Europe, Belgium road rules, https://europa.eu/youreurope/citizens/travel/driving-abroad/road-rules-and-safety/belgium/index_en.htm). Avenue: built-up area, 50; Brussels keeps 50 or 70 on its major axes (https://www.brussels.be/node/58875). Street: 30, the Brussels default on all other roads since 1 January 2021 (same page). Zone: 20 in residential and encounter zones (Brussels Mobility, https://be.brussels/en/transport-mobility/road-safety/safety-tips/limited-speed-everyone-benefits). Rural: 70 outside built-up areas in Flanders since 2017 and in Brussels; Wallonia is 90 (Brussels Times, https://brusselstimes.com/belgium/1460167/speed-limits-bike-lanes-key-traffic-rules-to-know-before-hitting-belgian-roads-tbtb; Wikipedia, Speed limits in Belgium). Confidence medium: the Flemish 70 was read in secondary pages, and a real ring or avenue can carry another posted limit.2026-11-19
Road class service and track speed, lanes and width of every class, the block and street size layout, the geometry of roadsservice 20 km/h, track 60 km/h; lanes ring 4, others 2 (track 1); widths ring 24, avenue 10, rural 7, street 8, zone 6, service 5, track 8 m; block 60 m, street 10 mkm/h, -, mPLACEHOLDER, design values. A works yard and a test track have no legal limit. Widths are chosen to fit the 10 m street between blocks (an avenue runs along a street line), not measured. Block and street size come from spec 09. Positions, the ring, the bridge deck height of 5.5 m, the circuit's lengths, its 100 m curve radius and its 6 % slopes are authored for the model town.-
Largest road slope, smallest height gap at a bridge0.10 (10 %), 4.5 m-, mPLACEHOLDER, validation limits of this project (MAX_SLOPE, MIN_CLEARANCE_M in roads.rs), not taken from a road standard. A road that is steeper, or that crosses another road without a junction and is less than 4.5 m above or below it, fails validation.-
Vehicle model of Drive (crates/city-core/src/vehicle.rs): road-load forces, battery power with drive efficiency, regeneration fraction and cap, auxiliary load, rotating-mass factor, peak powerformulas as in the Lemonergy Garage, battery-design commit 6b358ef0f68e05b3e4c2fe91e0bc7a00e0665ac4 (js/vehicle.js, js/terrain.js)W, WhOne model in two tools: copied from the Garage, not re-derived. Agreement is tested against numbers the Garage's own code produced (crates/city-core/tests/data/garage_agreement.json, made by tools/garage-fixtures.mjs, 11 cases, relative difference 1e-9). The Garage's references for the formulas: Gillespie, Fundamentals of Vehicle Dynamics, SAE R-114, 1992; Ehsani, Gao, Longo, Ebrahimi, Modern Electric, Hybrid Electric and Fuel Cell Vehicles, CRC Press, 3rd ed. 2018. Those books were not re-read for this project.2026-11-19
Constants g and air density9.80665 m/s2, 1.225 kg/m3m/s2, kg/m3Standard gravity (CGPM 1901) and the ISA sea-level air density; the values the Garage uses.2026-11-19
Terrain table: rolling resistance, speed factor, regeneration factor per surfaceas the Garage's js/terrain.js at the commit above-, - , -Copied from the Garage; the Garage's own sources for the values apply. Lemon City adds no terrain value. The surface of a road edge is the surface of its road class in city.json, unless the edge names its own (spec 17); a surface the vehicle file has no terrain for is an error in plain words.2026-11-19
Driving-mode factors (speed, acceleration, regeneration, auxiliary scale)as the Garage's modes at the commit above-Copied from the Garage. A route written by Lemon City carries the driven speeds, so the Garage reads it as a normal-mode trace.2026-11-19
Class-default vehicle values in web/public/vehicles/*.json (mass, Cd, frontal area, Crr, drive efficiency, regeneration fraction, auxiliary load, rotating mass)ev, ebus, ebike, escooter, robotkg, -, m2, -, -, -, W, -The Garage's class defaults at the commit above, taken by running the Garage code in tools/garage-fixtures.mjs.2026-11-19
Battery packs of those five example vehicles (pack.energyWh, dod, regenCapW, peakPowerW, massKg)ev 60 kWh, bus 300 kWh, e-bike 500 Wh, e-scooter 400 Wh, robot 20 kWhWh, -, W, W, kgPLACEHOLDER. Typed in tools/garage-fixtures.mjs so that the examples run; not a real product. A visitor's own vehicle comes from the Garage with its real pack.-
Driver values drive_params: comfort acceleration 1.5, comfort braking 2.0, lateral acceleration 1.5, dwell 20 s at a signal and 2 s at a priority junction, roundabout speed 25, simulation step 2 m, crawl speed 1, time step 1see leftm/s2, s, km/h, m, m/s, sPLACEHOLDER, design values (DriveParams::design), not measured. They set how stop-and-go the trip is and so the energy per km. They are in the result file, so a reader sees them.-
Build limits build.params: kinds allowed (all ten), most items 80, ground solar cover of a block 0.6, area per kWp 5, battery container 2,500, most containers on a block 6, road classes avenue, street, zone, servicesee left-, -, -, m2, kWh, -, -PLACEHOLDER, design values of the Build sandbox (spec 19), listed in placeholders as build.params. Area per kWp and the container size are the same numbers as AREA_PER_KWP_M2 and KWH_PER_CONTAINER in the scene; a test holds them equal.-
What a placed thing is made of (rooftop kWp per roof area, green-roof area per roof area, pocket-park area, battery power and efficiency per capacity, charger hub, wind turbine, building group)copied from the reference town's entries of the same kind-Derived, no new number: every figure is the reference city's own value for that kind, scaled by footprint or count (crates/city-core/src/build.rs). Whatever is a placeholder in the reference city stays a placeholder when built.-
Challenge goals in web/public/build/challenges.json (self-sufficiency at least 0.5, green space at least 45 m2 per person, carbon at most 1,300 kg per person, and one of both at once)see left-, m2, kgPLACEHOLDER, design goals for a game of building, chosen so a visitor can reach them in the New Quarter (a test builds one way to each). They are not targets from any source or standard.-
Fleet scenario "every car were this one"the simulated Wh/km of the route replaces transport.kwh_per_kmkWh/kmNot a source: a labelled scenario. The road mix is the route's own and is shown per class; the town is marked as a scenario until reset.-